Ordering considerations
Precautions for ordering PT500-590 products
1. Product range selection:
In order to achieve the best effect of product accuracy, service life, stability and other functions, the range of the product is calculated according to the following formula:
Range = x (1.2-1.5) times the maximum pressure of the system;
The actual measuring pressure range of the product should be 15% - 80% of the measuring range;
Temperature range: distinguish between measuring temperature and medium. The required product is measuring medium temperature or testing ambient temperature. Explain the situation with the salesperson when ordering;
2. Product power supply and output:
The selection of power supply range is determined according to the output specifications of the product:
A. Built in battery 3.6v1200mah;
B. External 5VDC power supply;
C. External 9-24vdc power supply;
Conventional Modbus rs485-rtu low-power digital output;
5-digit LCD display meter; The default acquisition time is 1s / time;
3. Users need to understand the characteristics of the measuring medium of the product:
Medium specification, medium temperature, medium purity (whether it contains impurities or particles, etc.);
4. Users should understand the installation environment and installation method of the product:
Indoor or outdoor installation;
Ambient temperature;
Required sealing grade;
Vibration range of equipment;
Installation method: thread, flange and special structure;
Whether the installation space meets the overall dimension of the product;